| Order reference AM85uv-wxyz
 |  | 
		
			| u | flange code F | 
		
			| v | motor length | 
		
			| w = 0 | smooth shaft | 
		
			| w = 1 | shaft with groove and feather key according to DIN 6885 | 
		
			| w = 2 | shaft with IP 65 sealing ring and smooth shaft | 
		
			| w = 3 | shaft with IP 65 sealing ring and shaft with groove and feather key | 
		
			| x | winding code A…Z | 
		
			| y = 0 | 2-cable standard: feedback resolver | 
		
			| y = 1 | One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, single-turn, absolute position within one revolution, 18 bit resolution | 
		
			| y = 2 | One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, multi-turn, absolute position within 4,096 revolutions, 18 bit resolution | 
		
			| y = 4 | 2-cable standard: feedback multi-turn, absoulte encoder SKM36, 128 sincos periods (only for AM856x) | 
		
			| y = A | One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, single-turn, absolute position within one revolution, resolution 23 bit | 
		
			| y = B | One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, multi-turn, absolute position within 4096 revolutions, resolution 23 bit | 
		
			| z = 0 | without holding brake | 
		
			| z = A | forced cooling, without holding brake, for AM855x, AM856x (1) | 
		
			|  | (1) The EL2022 or KL2022 digital output terminal is recommended for controlling the external 24 V DC ventilation. | 
		
			|  | All electric quantities are RMS values. | 
		
			|  | The options cannot be installed in the field. |