| Output  | potential-free  | 
        
            | Output signal  | 4...20mA or 20...4mA  | 
        
            | Load resistance  | <500Ohm  | 
        
            | System resolution  | <0,2μA  | 
        
            | Repeatability  | <6μm  | 
        
            | Hysteresis  | <4μm  | 
        
            | max. non-linearity  | +-100μm up to L=500mm; 0,02% FS at L>500mm  | 
        
            | Update time  | 1kHz  | 
        
            | Housing material  | Anodized aluminium  | 
        
            | Operating voltage  | 24VDC +-20%  | 
        
            | max. ripple  | <5mV  | 
        
            | Current draw  | <150mA  | 
        
            | Polarity reversal protected  | yes  | 
        
            | Overvoltage protection  | Transzorb protection diodes  | 
        
            | Temperature coefficient of overall system  | [150μV/°C+(5ppm/°CxPxU/L)]x(T2-T1)  | 
        
            | Operating temperature  | -40...+85°C  | 
        
            | Storage temperature  | -40...+100°C  | 
        
            | Static electricity (ESD)  | IEC 1000-4-2 Severity Level 3  | 
        
            | Electromagnetic fields (RFI)  | IEC 1000-4-3 Severity Level 3  | 
        
            | Fast transients (BURST)  | IEC 1000-4-4 Severity Level 4  | 
        
            | Line-carried noise  | IEC 1000-4-6 Severity Level 3  | 
        
            | RF emission  | EN 55011 Group 1, Class A  | 
        
            | Shock loading  | 100g / 1ms per IEC68-2-27  | 
        
            | Vibration  | 12g, 10...2000Hz per IEC68-2-6  | 
        
            | Dielectric strength  | 500V (GND to housing)  | 
        
            | Traverse velocity of magnet  | any  | 
        
            | Enclosure rating per IEC 529  | IP 67 (when BKS-S32/33 is installed)  | 
        
            | Accessories  | mounting clamps with isolating bushings and screws are  | 
        
            |   | included. magnet and connector (please order separately)  |