Order reference 
				AM85uv-wxyz | 
			
				  | 
		
		
			| 
				u | 
			
				flange code F | 
		
		
			| 
				v | 
			
				motor length | 
		
		
			| 
				w = 0 | 
			
				smooth shaft | 
		
		
			| 
				w = 1 | 
			
				shaft with groove and feather key according to DIN 6885 | 
		
		
			| 
				w = 2 | 
			
				shaft with IP 65 sealing ring and smooth shaft | 
		
		
			| 
				w = 3 | 
			
				shaft with IP 65 sealing ring and shaft with groove and feather key | 
		
		
			| 
				x | 
			
				winding code A…Z | 
		
		
			| 
				y = 0 | 
			
				2-cable standard: feedback resolver | 
		
		
			| 
				y = 1 | 
			
				One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, single-turn, absolute position within one revolution, 18 bit resolution | 
		
		
			| 
				y = 2 | 
			
				One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, multi-turn, absolute position within 4,096 revolutions, 18 bit resolution | 
		
		
			| 
				y = 4 | 
			
				2-cable standard: feedback multi-turn, absoulte encoder SKM36, 128 sincos periods (only for AM856x) | 
		
		
			| 
				y = A | 
			
				One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, single-turn, absolute position within one revolution, resolution 23 bit | 
		
		
			| 
				y = B | 
			
				One Cable Technology for power and feedback: feedback transmission via motor cable, no feedback cable necessary, electronic identification plate, multi-turn, absolute position within 4096 revolutions, resolution 23 bit | 
		
		
			| 
				z = 0 | 
			
				without holding brake | 
		
		
			| 
				z = A | 
			
				forced cooling, without holding brake, for AM855x, AM856x (1) | 
		
		
			| 
				  | 
			
				(1) The EL2022 or KL2022 digital output terminal is recommended for controlling the external 24 V DC ventilation. | 
		
		
			| 
				  | 
			
				All electric quantities are RMS values. | 
		
		
			| 
				  | 
			
				The options cannot be installed in the field. |