Pressure by regulators to set up an electrical signal.
	- 
		Precision Control 
 
	- 
		1.5% FS linearity, precision control is possible that pressure hysteresis 1.0% FS. 
 
	- 
		Excellent pressure characteristics 
 
	- 
		Output voltage variation for the primary pressure change is less than 0.5% FS. 
 
	- 
		Flow characteristic 
 
	- 
		As with the normal pressure reducing valve, ensuring a ready flow directly to the pneumatic equipment. In addition, reproducibility for intermittent load is less than 0.5% FS. 
 
	- 
		Free mounting orientation 
 
	- 
		There are no restrictions on mounting orientation. However, after installation is required zero and span adjustments. 
 
	- 
		Wide adjustment range 
 
	- 
		The span adjustment screw, RT · E/P-8-2 is 0.65 ~ 0.84MPa, RT · I/P-8-2 can change its point of each span in the range of 0.24 ~ 0.84MPa. 
 
	- 
		Compact 
 
	- 
		Compact main dimensions of 54 × 105. Takes up space.
 
	
	
		
			
				| 
					RT · E/P-8-2 | 
				
					RT · I/P-8-2 | 
				
					RT · I/P-1-2 | 
			
			
				| 
					Fluid | 
				
					Compressed air cleaning | 
			
			
				| 
					Pressure range (MPa) | 
				
					0.02 to 0.82 | 
				
					0.02 to 0.1 | 
			
			
				| 
					Outlet pressure range of 1 (MPa) | 
				
					1.MAX, 
					Above the set pressure +0.035 | 
				
					0.7.MAX, 
					Above the set pressure +0.02 | 
			
			
				| 
					Input signal | 
				
					Control scheme | 
				
					Voltage 2-wire | 
				
					Current 2-wire | 
			
			
				| 
					Voltage (VDC) | 
				
					0-10 | 
				
					- | 
			
			
				| 
					Input Impedance (Ω) | 
				
					805 | 
				
					- | 
			
			
				| 
					Current (mADC) | 
				
					- | 
				
					4-20 | 
			
			
				| 
					Input Impedance (Ω) | 
				
					- | 
				
					260 | 
				
					180 | 
			
			
				| 
					Linearity (%. FS) | 
				
					1.5 | 
			
			
				| 
					Hysteresis (%. FS) | 
				
					1.0 | 
			
			
				| 
					Repeatability (%. FS) | 
				
					± 0.1 | 
				
					± 0.5 | 
			
			
				| 
					Step response (sec) | 
				
					1.0 | 
				
					0.2 | 
			
			
				| 
					Lower limit span adjustment (MPa) | 
				
					0.65 | 
				
					0.24 | 
				
					0.08 | 
			
			
				| 
					Sensitivity Relief (MPa) | 
				
					Below the set pressure + 0.001 | 
			
			
				| 
					Air consumption (Nl / min) | 
				
					Below 3.7 | 
				
					Below 4.8 | 
			
			
				| 
					Operating Temperature Range (℃) | 
				
					5-60 | 
			
			
				| 
					Port size (Rc) | 
				
					1 / 4 | 
			
			
				| 
					Pressure gauge port size (Rc) | 
				
					1 / 4 | 
			
			
				| 
					Bracket | 
				
					Standard equipment | 
			
			
				| 
					Weight (kg) | 
				
					0.94 |