| Technical Data Features   | 
        
            | Control Types | Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat & cool | 
        
            | Auto/Manual | Selectable from front panel or via digital input, with bumpless transfer | 
        
            | Output Configuration | Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint | 
        
            | Alarm 1 & 2 Types | Process high, process low, SP deviation, band, logical OR / AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis. | 
        
            | Human Interface | 4 button operation, dual 4 digit 10mm & 8mm high LED displays, optional choice of colours (Red/Red, Red/Green, Green/Red or Green/Green), plus 5 LED indicators | 
        
            | PC Configuration | Off-line configuration from PC serial port to dedicated config socket (comms option not required). Configuration Software for Windows 98 or higher. West Part Number: PS1-CON | 
        
            | Input | 
        
            | Thermocouple | J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%. | 
        
            | RTD | 3 Wire PT100, 50Ω per lead maximum (balanced) | 
        
            | DC Linear | 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V. Scaleable  -1999 to 9999, with adjustable decimal point | 
        
            | Impedance | >10MΩ for Thermocouple and mV ranges, 47KΩ for V ranges and 5Ω for mA ranges | 
        
            | Accuracy | ±0.1% of input range ±1 LSD (T/C CJC better than 1°C) | 
        
            | Sampling | 4 per second, 14 bit resolution approximately | 
        
            | Sensor Break Detection | <2 seconds (except zero based DC ranges), control O/P’s turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges | 
        
            | Outputs & Options | 
        
            | Control & Alarm Relays | Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations | 
        
            | Control SSR Driver Outputs | Drive capability >10V DC in 500Ω minimum | 
        
            | Triac Outputs | 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz | 
        
            | DC Linear Outputs | 0 to 20mA, 4 to 20mA into 500Ω max, 0 to 10V, 2 to 10V, 0 to 5V into 500Ω min. Control outputs have 2% over/under drive applied. Accuracy ±0.25% at 250Ω (degrades linearly to 0.5% for increasing burden to specified limits) | 
        
            | Transmitter Power Supply | Output 24VDC (nominal) into 910Ω minimum to power external devices | 
        
            | Communications | 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable) | 
        
            | Digital Input | Selects between 2 setpoints or Auto/Manual control. Volt free or TTL input | 
        
            | Remote Setpoint Input | 0 to 20mA, 4 to 20mA, 0 to 5V, 1 to 5V, 0 to 10V or 2 to 10V.Scaleable -1999 to 9999. Local/Remote setpoint selected from front panel | 
        
            | Operating & Environmental | 
        
            | Temperature & RH | 0 to 55°C (-20 to 80°C storage), 20% to 95% RH non-condensing | 
        
            | Power Supply | 100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) | 
        
            | Front Panel Protection | IEC IP66 (Behind panel protection is IP20) | 
        
            | Standards | CE, UL & ULC recognised |