				Shipping date | 
			
				  View | 
		
		
			| 
				Mounting type  | 
			
				Mounting plate, bolted 
				with top-hat rail | 
		
		
			| 
				Assembly position  | 
			
				Free convection 
				Vertical | 
		
		
			| 
				Product weight  | 
			
				350 g | 
		
		
			| 
				Display  | 
			
				LED green/yellow/red | 
		
		
			| 
				Authorisation  | 
			
				RCM Mark 
				c UL us - Listed (OL) | 
		
		
			| 
				KC mark  | 
			
				KC-EMV | 
		
		
			| 
				CE mark (see declaration of conformity)  | 
			
				to EU directive for EMC 
				to EU directive for machinery 
				in accordance with EU RoHS directive | 
		
		
			| 
				Certificate issuing department  | 
			
				TÜV Rheinland 01/205/5696.00/19 
				UL E331130 | 
		
		
			| 
				Storage temperature  | 
			
				-25 ... 55 °C | 
		
		
			| 
				Ambient temperature  | 
			
				0 ... 50 °C | 
		
		
			| 
				Note on ambient temperature  | 
			
				Observe derating with regard to mounting clearance and output current | 
		
		
			| 
				Relative air humidity  | 
			
				5 - 90 % 
				non-condensing | 
		
		
			| 
				Max. installation height  | 
			
				2,000 m | 
		
		
			| 
				Protection class  | 
			
				IP20 | 
		
		
			| 
				Safety class  | 
			
				III | 
		
		
			| 
				Overvoltage category  | 
			
				I | 
		
		
			| 
				Degree of contamination  | 
			
				2 | 
		
		
			| 
				Materials note  | 
			
				Contains PWIS substances 
				Conforms to RoHS | 
		
		
			| 
				Nominal voltage, load supply DC  | 
			
				24 ... 48 V | 
		
		
			| 
				Permissible range, load supply  | 
			
				-15 % / +15 % | 
		
		
			| 
				Max. intermediate circuit voltage, DC  | 
			
				60 V | 
		
		
			| 
				Nominal DC voltage, logic power supply  | 
			
				24 V | 
		
		
			| 
				Permissible range, logic voltage  | 
			
				± 15 % | 
		
		
			| 
				Current consumption, logic power supply without clamping brake  | 
			
				1 A | 
		
		
			| 
				Current consumption for logic supply with locking brake  | 
			
				2 A | 
		
		
			| 
				Output voltage range AC  | 
			
				0 V up to input voltage | 
		
		
			| 
				Nominal output current  | 
			
				8 A | 
		
		
			| 
				Effective nominal current per phase  | 
			
				8 A | 
		
		
			| 
				Effective peak current per phase  | 
			
				10 A | 
		
		
			| 
				Max. peak current duration  | 
			
				3 s | 
		
		
			| 
				Nominal controller power  | 
			
				300 W | 
		
		
			| 
				Peak power  | 
			
				400 W | 
		
		
			| 
				Output frequency  | 
			
				0 ... 20,000 Hz | 
		
		
			| 
				Max. length of motor cable without external mains filter  | 
			
				25 m | 
		
		
			| 
				Max. output current of holding brake  | 
			
				1 A | 
		
		
			| 
				Max. voltage drop from logic supply to brake output  | 
			
				1 V | 
		
		
			| 
				Controller operating mode  | 
			
				Cascade controller 
				P position controller 
				PI speed controller 
				PI current regulator for F or M 
				Profile operation with record and direct mode 
				Interpolated mode via fieldbus 
				Synchronised operating modes 
				Homing 
				Setting-up 
				Autotuning 
				Open-loop operation | 
		
		
			| 
				Operating mode  | 
			
				Field-oriented closed-loop control 
				Position resolution 24 bit/U 
				Sampling rate 20 kHz 
				Pulse-width modulation with 20 kHz 
				Real-time data acquisition 
				2x Input-Capture (x, v, F) 
				2x Output-Trigger (x, v, F) 
				1x position sensor input | 
		
		
			| 
				Adjustable current reduction  | 
			
				Using software | 
		
		
			| 
				Protective function  | 
			
				I²t monitoring 
				Temperature monitoring 
				Current monitoring 
				Voltage failure detection 
				Drag error monitoring 
				Software end-position detection | 
		
		
			| 
				Nominal current adjustment  | 
			
				Using software | 
		
		
			| 
				Ethernet interface, function  | 
			
				Parameterisation and commissioning | 
		
		
			| 
				Ethernet interface, protocol  | 
			
				TCP/IP | 
		
		
			| 
				Fieldbus interface, protocol  | 
			
				PROFINET IRT 
				PROFINET RT | 
		
		
			| 
				Communications profile  | 
			
				PROFIdrive 
				PROFIenergy | 
		
		
			| 
				Process interface  | 
			
				AC1: Adj.-Speed Drives 
				AC3: Drive w. Positioning Func 
				AC4: Synchr. Servo Application | 
		
		
			| 
				Fieldbus interface, transmission rate  | 
			
				100 Mbit/s | 
		
		
			| 
				Fieldbus interface, type of connection  | 
			
				2x socket | 
		
		
			| 
				Fieldbus interface, connection technology  | 
			
				RJ45 | 
		
		
			| 
				Encoder interface, function  | 
			
				BiSS-C 
				Incremental encoder | 
		
		
			| 
				Number of digital logic inputs  | 
			
				6 | 
		
		
			| 
				Input circuit logic  | 
			
				NPN (negative switching) 
				PNP (positive-switching) | 
		
		
			| 
				Logic input characteristics  | 
			
				Freely configurable to a given extent 
				Safety inputs in some cases 
				Not electrically isolated | 
		
		
			| 
				Specification, logic input  | 
			
				Based on IEC 61131-2, type 3 | 
		
		
			| 
				Logic input working range  | 
			
				-3 ... 30 V | 
		
		
			| 
				Number of high-speed logic inputs  | 
			
				2 | 
		
		
			| 
				Time resolution of high-speed logic inputs  | 
			
				1 µs | 
		
		
			| 
				Number of 24 V DC digital logic outputs  | 
			
				2 | 
		
		
			| 
				Switching logic, outputs  | 
			
				NPN (negative switching) 
				PNP (positive-switching) | 
		
		
			| 
				Digital logic output characteristics  | 
			
				configurable 
				Not electrically isolated | 
		
		
			| 
				Max. current, digital logic outputs  | 
			
				100 mA | 
		
		
			| 
				Number of high-speed switching outputs  | 
			
				2 | 
		
		
			| 
				Time resolution of high-speed switching outputs  | 
			
				1 µs | 
		
		
			| 
				Number of floating switching outputs  | 
			
				1 | 
		
		
			| 
				Max. current of the floating switching outputs  | 
			
				100 mA | 
		
		
			| 
				Safety function  | 
			
				Safe torque off (STO) 
				Safe stop 1 (SS1-time controlled) | 
		
		
			| 
				Safety Integrity Level (SIL)  | 
			
				STO / SIL 2 / SILCL 2 (EC motor without diagnostics) 
				STO / SIL 3 / SILCL 3 (stepper motor/EC motor with diagnostics) | 
		
		
			| 
				Performance level (PL)  | 
			
				STO / cat. 3 PLd (EC motor without diagnostics) 
				STO / cat. 3, PLe (stepper motor/EC motor with diagnostics) | 
		
		
			| 
				Diagnostic coverage  | 
			
				STO: 87% (EC motor without diagnostics) 
				STO / 90% (stepper motor) 
				STO: 92% (EC motor with diagnostics) | 
		
		
			| 
				Hardware fault tolerance  | 
			
				1 | 
		
		
			| 
				Proof test interval  | 
			
				STO / 20 a (stepper motor/EC motor without diagnostics) | 
		
		
			| 
				Number of safe 2-pin inputs  | 
			
				1 | 
		
		
			| 
				Number of diagnostic outputs  | 
			
				1 |