Measurement range in terms of flow velocity: 
0 – 0.3 m/s to 0 –10 m/s (0 –1.0 ft/s to 0 – 32.8 ft/s). 
0 – 0.1 m/s to 0 – 0.3 m/s (0 – 0.3 ft/s to 0 – 1.0 ft/s) 
range is available optionally. 
Accuracy:  
< 1/2" to 18" ( 15mm to 450mm )> 
±0.2 % of Rate* 
* This pulse output error result is established under standard 
operating conditions at Toshiba's admitted flow calibration 
facility. 
* Individual meter measurement error may vary up to ±0.5% of 
Rate at 1.64 ft/s (0.5m/s) or more and ±0.3% of rate ±0.039 
inch/s (1mm/s) at 1.64 ft/s or less. 
* Current output: plus ± 8μA (0.05% of span.) 
* Refer to individual calibration data for each individual 
meter's measurement error. 
< 20" and 24" ( 500mm and 600mm )> 
±0.3 % of Rate* 
* This pulse output error result is established under standard 
operating conditions at Toshiba's admitted flow calibration 
facility. 
* Individual meter measurement error may vary up to ±0.5% of 
Rate at 3.28 ft/s (1.0m/s) or more and ±0.3% of rate ±0.079 
inch/s (2mm/s) at 3.28 ft/s (1.0m/s) or less. 
* Current output: plus ± 8μA (0.05% of span.) 
* Refer to individual calibration data for each individual 
meter's measurement error.