| Shipping date |  View | 
		
			| Mounting type | On sub-base Tightened
 with top-hat rail
 | 
		
			| Product weight | 290 g | 
		
			| Display | LED green/red Seven-segment display
 | 
		
			| Authorisation | RCM Mark c UL us - Listed (OL)
 | 
		
			| KC mark | KC-EMV | 
		
			| CE mark (see declaration of conformity) | to EU directive for EMC to EU directive for machinery
 in accordance with EU RoHS directive
 | 
		
			| Certificate issuing department | 01/205/5252.02/20 TÜV Rheinland
 | 
		
			| Storage temperature | -25 ... 75 °C | 
		
			| Ambient temperature | 0 ... 50 °C | 
		
			| UL ambient temperature | 0 ... 40 °C | 
		
			| Relative air humidity | 0 - 90 % non-condensing
 | 
		
			| Protection class | IP40 | 
		
			| Materials note | Conforms to RoHS | 
		
			| Nominal current, load supply | 6 A | 
		
			| Peak current, load supply | 8 A | 
		
			| Mains filter | Integrated | 
		
			| Nominal voltage, load supply DC | 24 V | 
		
			| Max. intermediate circuit voltage, DC | 31 V | 
		
			| Braking resistance | 15 Ohm | 
		
			| Braking resistance pulse power | 0,1 kVA | 
		
			| Nominal DC voltage, logic power supply | 24 V | 
		
			| Permissible range, logic voltage | ± 15 % | 
		
			| Nominal current, logic supply | 0,3 A | 
		
			| Nominal output current | 5,7 A | 
		
			| Controller operating mode | PWM-MOSFET power output stage Cascade controller with
 P position controller
 PI speed controller
 Proportional and integral controller for electricity
 | 
		
			| Adjustable current reduction | Using software | 
		
			| Step adjustment | Using software | 
		
			| Protective function | I²t monitoring Temperature monitoring
 Current monitoring
 Voltage failure detection
 Drag error monitoring
 Software end-position detection
 | 
		
			| Nominal current adjustment | Using software | 
		
			| Parameters configuring interface | Ethernet | 
		
			| Ethernet, supported protocols | TCP/IP, Modbus TCP | 
		
			| Protocol | FHPP I-Port
 IO-Link
 Modbus TCP
 | 
		
			| Fieldbus coupling | Ethernet | 
		
			| Communications profile | FHPP | 
		
			| IO-Link, connection technology | Cage Clamp | 
		
			| IO-Link, protocol | Device V 1.1 | 
		
			| IO-Link, communication mode | COM3 (230.4 kbd) | 
		
			| IO-Link, number of ports | Device 1 | 
		
			| IO-Link, process data width OUT | Parameterisable 8 or 16 bytes | 
		
			| IO-Link, process data content OUT | Parameterisable FHPP or FHPP+FPC | 
		
			| IO-Link, process data width IN | Parameterisable 8 or 16 bytes | 
		
			| IO-Link, process data content IN | Parameterisable FHPP or FHPP+FPC | 
		
			| IO-Link, minimum cycle time | 1 ms | 
		
			| Rotor position sensor | Encoder | 
		
			| Position sensor | Encoder | 
		
			| Encoder interface input, characteristics | RS422 | 
		
			| Number of digital logic inputs | 1 | 
		
			| Input circuit logic | PNP (positive-switching) | 
		
			| Logic input characteristics | galvanically connected to logic potential | 
		
			| Specification, logic input | Based on IEC 61131-2 | 
		
			| Logic input working range | 24 V | 
		
			| Number of 24 V DC digital logic outputs | 3 | 
		
			| Switching logic, outputs | PNP (positive-switching) | 
		
			| Digital logic output characteristics | Freely configurable to a given extent Not electrically isolated
 | 
		
			| Max. current, digital logic outputs | 100 mA | 
		
			| Safety function | Safe torque off (STO) | 
		
			| Safety Integrity Level (SIL) | Safe torque off (STO)/SIL 3 | 
		
			| Performance level (PL) | Safe torque off (STO)/category 3, Performance Level e |