            CHARACTERISTIC 
             | 
            
             UMV   4301 
            1.5T to 16T - 1TL to 8TL 
             | 
            
             UMV   4301 
            22T to 50T - 11TL to 33TL 
             | 
            
             UMV 4301 
            60T to 120T 
             | 
        
        
            | 
               
              
            Regulation mode 
             | 
            
             •   Vector control, open loop 
            •   Vector control, closed loop 
            •   Voltage/frequency ratio (V/F) 
            •   Servomotor 
             | 
        
        
            | 
               
            Regulation 
             | 
            
             •   Speed reference 
            •   Torque reference (regulation of motor current) 
             | 
        
        
            | 
             Constant torque 
            Constant power 
             | 
            
               
            Adjusted by basic frequency 
             | 
        
        
            | 
               
            Switching frequency 
             | 
            
             3 - 4.5 - 6 - 9 and 12 kHz 
            Depending on the   rating, derating according to the switching frequency or automatic adjustment   of the switching frequency according to the load 
             | 
        
        
            | 
               
            Overload capacity 
             | 
            
             •   150 % of controller rated current for 60s 
            •   175 % of controller rated current for 4s (in servomotor mode) 
             | 
        
        
            | 
               
            Braking 
             | 
            
             •   Hypersynchronous. Controller alone or with RF options 
            •   By DC injection 
             | 
        
        
            | 
               
            Speed feedback for   closed loop operation 
             | 
            
             •   By incremental encoder (2 complementary channels + 0 marker) 
            • By incremental encoder (2 complementary   channels + 0 marker   + 3 complem. channels   per phase U, V, W) in servomotor mode 
            •   By resolver + RLV UMV option   card in servomotor mode 
             | 
        
        
            | 
               
            CONTROL 
             | 
        
        
            | 
               
            Control logic 
             | 
            
             • Negative      {   high level     >   + 15V 
            • Positive                  low   level      < +  5V 
             | 
        
        
            | 
               
              
              
            Speed references 
             | 
            
             •   Analogue : 
            - differential voltage ± 10V   (input impedance : 100 KΩ) 
            - voltage 0/± 10V   in common mode (input impedance : 100 KΩ) 
            - current 0-20mA, 4-20mA or 20-0mA,   20-4mA 
            •   Digital : 
            - from keypad 
            - by jogging 
             | 
        
        
            | 
               
              
            Torque reference 
             | 
            
             •   Analogue : 
            - voltage 0/± 10V   in common mode (input impedance : 100 KΩ) 
            - current 0-20mA, 4-20mA or 20-0mA,   20-4mA (input impedance : 100 Ω) 
            •   Digital : 
            - from keypad by incrementation 
             | 
        
        
            | 
               
            Speed regulation 
             | 
            
             Adjustment by   programming the " proportional " and " integral " and   " derivative " coefficients of the speed loop 
             | 
        
        
            | 
               
            Forward/reverse control 
             | 
            
             •   By inversion of the reference polarity 
            •   By logic input 
            •   From the operator console 
             | 
        
        
            | 
             Self-adaptation of   the controller to the motor 
             | 
            
             Measurement of the motor   characteristics (cos ϕ, magnetizing   current and stator resistance) 
            and the encoder feedback. 
             | 
        
        
            | 
               
            OPERATION 
             | 
        
        
            | 
             Acceleration / deceleration ramps 
             | 
            
             Separate settings from 0 to 3200s.   Linear or " S " curve. The radius of the " S " ramp can   be adjusted. 
             | 
        
        
            | 
             Minimum/maximum speed limit 
             | 
            
             Speed variation between two stops. 
             | 
        
        
            | 
               
            Stopping mode 
             | 
            
             •   Freewheel stop : by logic input (terminal 30) immediate cut-off of   motor power supply. 
            •   Stop on ramp (following different modes). 
            •   DC injection braking stop. 
            •   Orientation stop in specific position (closed loop). 
             | 
        
        
            | 
             Dynamic V/F selection 
             | 
            
             Automatic adaptation of the V/F curve   to the motor load in V/F mode. 
             | 
        
        
            | 
             Flying restart 
             | 
            
             Ability of the controller to start while the   motor is running. 
             |