Technical data (20°C)
|
Measurement range
|
From 0… 100 mbar to 0… 40 bar vacuum, com-
|
Zero thermal drift ±0.025% of F.S / °C max.
|
|
pound, gauge or absolute pressure
|
Option: ±0.015% of F.S / °C max.
|
Output signal
|
E612: 0...10 Vdc
|
Span thermal drift Typically: ±0.01%/°C / max.: ±0.015%/°C
|
|
E613: 4...20 mA
|
Wetted parts Ceramic + 1.4404 (316L) stainless steel + NBR
|
|
E614: 1...5 Vdc
|
seal (standard)
|
Supply voltage
|
E612: 14...40 Vdc
|
Standard connections Electrical: Connector DIN 43650
|
|
E613-E614: 8...40 Vdc
|
Pressure: G1/2
|
|
Protection against polarity inversion
|
Many options available
|
Insulation
|
> 100 MΩ at 250 Vdc. Option: 500 Vdc.
|
Protection rating (EN 60529) Standard: IP65 (Connector DIN)
|
Maximum input current
|
E612-E614: 6 mA
|
Option: IP67 (depending on connector)
|
Load impedance (+M/-M)
|
E612: ≥ 2.5 k Ω
|
Typical response time < 30 ms
|
|
E614: ≥ 1 k Ω E613: (Usupply-24)/0,02 ≤ RΩ ≤ (Usupply-8)/0,02
|
Vibration resistance (IEC 68-2-6) 1.5 mm (10 - 55 Hz), 20 g (55 Hz - 2 kHz) Shock resistance (IEC 68-2-32) 25 falls from 1 m on to a concrete floor
|
CE Conformity
|
89/336 EMC directive CE with screened cable,
|
|
|
screen connected at both ends
|
|
|
97/23/CE PED pressure directive
|
|
Accuracy
|
±0.5% of F.S.
|
|
Linearity, hysteresis, repeatability
|
±0.2% of F.S. (reference to BFSL)
|
|
Operating temperature Ambient (Ta)
|
-25...+85°C (only
|
|
Option
|
Low t°: -40...+85°C (only for seal NBR)
|
|
|
High t°: -25...+100°C (only for DIN 43650 connector)
|
|
Fluid temperature
|
-25...+100°C (Ta ≤ 50°C)
|
|
Storage temperature
|
-40...+85°C
|
|
Compensated temperature range -25...+85°C
|
(zero and sensitivity)
|