CHARACTERISTIC
|
UMV 4301
1.5T to 16T - 1TL to 8TL
|
UMV 4301
22T to 50T - 11TL to 33TL
|
UMV 4301
60T to 120T
|
Regulation mode
|
• Vector control, open loop
• Vector control, closed loop
• Voltage/frequency ratio (V/F)
• Servomotor
|
Regulation
|
• Speed reference
• Torque reference (regulation of motor current)
|
Constant torque
Constant power
|
Adjusted by basic frequency
|
Switching frequency
|
3 - 4.5 - 6 - 9 and 12 kHz
Depending on the rating, derating according to the switching frequency or automatic adjustment of the switching frequency according to the load
|
Overload capacity
|
• 150 % of controller rated current for 60s
• 175 % of controller rated current for 4s (in servomotor mode)
|
Braking
|
• Hypersynchronous. Controller alone or with RF options
• By DC injection
|
Speed feedback for closed loop operation
|
• By incremental encoder (2 complementary channels + 0 marker)
• By incremental encoder (2 complementary channels + 0 marker + 3 complem. channels per phase U, V, W) in servomotor mode
• By resolver + RLV UMV option card in servomotor mode
|
CONTROL
|
Control logic
|
• Negative { high level > + 15V
• Positive low level < + 5V
|
Speed references
|
• Analogue :
- differential voltage ± 10V (input impedance : 100 KΩ)
- voltage 0/± 10V in common mode (input impedance : 100 KΩ)
- current 0-20mA, 4-20mA or 20-0mA, 20-4mA
• Digital :
- from keypad
- by jogging
|
Torque reference
|
• Analogue :
- voltage 0/± 10V in common mode (input impedance : 100 KΩ)
- current 0-20mA, 4-20mA or 20-0mA, 20-4mA (input impedance : 100 Ω)
• Digital :
- from keypad by incrementation
|
Speed regulation
|
Adjustment by programming the " proportional " and " integral " and " derivative " coefficients of the speed loop
|
Forward/reverse control
|
• By inversion of the reference polarity
• By logic input
• From the operator console
|
Self-adaptation of the controller to the motor
|
Measurement of the motor characteristics (cos ϕ, magnetizing current and stator resistance)
and the encoder feedback.
|
OPERATION
|
Acceleration / deceleration ramps
|
Separate settings from 0 to 3200s. Linear or " S " curve. The radius of the " S " ramp can be adjusted.
|
Minimum/maximum speed limit
|
Speed variation between two stops.
|
Stopping mode
|
• Freewheel stop : by logic input (terminal 30) immediate cut-off of motor power supply.
• Stop on ramp (following different modes).
• DC injection braking stop.
• Orientation stop in specific position (closed loop).
|
Dynamic V/F selection
|
Automatic adaptation of the V/F curve to the motor load in V/F mode.
|
Flying restart
|
Ability of the controller to start while the motor is running.
|