Output
|
potential-free
|
Output signal
|
4...20mA or 20...4mA
|
Load resistance
|
<500Ohm
|
System resolution
|
<0,2μA
|
Repeatability
|
<6μm
|
Hysteresis
|
<4μm
|
max. non-linearity
|
+-100μm up to L=500mm; 0,02% FS at L>500mm
|
Update time
|
1kHz
|
Housing material
|
Anodized aluminium
|
Operating voltage
|
24VDC +-20%
|
max. ripple
|
<5mV
|
Current draw
|
<150mA
|
Polarity reversal protected
|
yes
|
Overvoltage protection
|
Transzorb protection diodes
|
Temperature coefficient of overall system
|
[150μV/°C+(5ppm/°CxPxU/L)]x(T2-T1)
|
Operating temperature
|
-40...+85°C
|
Storage temperature
|
-40...+100°C
|
Static electricity (ESD)
|
IEC 1000-4-2 Severity Level 3
|
Electromagnetic fields (RFI)
|
IEC 1000-4-3 Severity Level 3
|
Fast transients (BURST)
|
IEC 1000-4-4 Severity Level 4
|
Line-carried noise
|
IEC 1000-4-6 Severity Level 3
|
RF emission
|
EN 55011 Group 1, Class A
|
Shock loading
|
100g / 1ms per IEC68-2-27
|
Vibration
|
12g, 10...2000Hz per IEC68-2-6
|
Dielectric strength
|
500V (GND to housing)
|
Traverse velocity of magnet
|
any
|
Enclosure rating per IEC 529
|
IP 67 (when BKS-S32/33 is installed)
|
Accessories
|
mounting clamps with isolating bushings and screws are
|
|
included. magnet and connector (please order separately)
|