PERFECT AUTOMATION SOLUTION
English Japan

Pressure sensor SPAN-P10R-G18F-PNLK-PNVBA-L1 8134897 Festo

Pressure sensor SPAN-P10R-G18F-PNLK-PNVBA-L1  8134897 Festo
Chuyên mục : Sabo Sensors
Nhà sản xuất : Đại lý Festo Vietnam
Hàng sẵn kho : Đặt hàng 
Mô tả:
Thông số chi tiết :

Thông số kỹ thuật Pressure sensor SPAN-P10R-G18F-PNLK-PNVBA-L1  8134897 Festo

Short type code
SPAN
Electrical connection 1, connector system
Connection pattern L1J
Electrical connection 1, connection pattern
00995428
KC mark
KC-EMV
Electrical connection 1, connection type
Plugs
Electrical connection 1, number of connections/cores
4
Start value for pressure measuring range
0 MPa
End value for pressure measuring range
145 psi
Overload pressure
1.5 MPa
Overload pressure
15 bar
End value for pressure measuring range
1 MPa
Overload pressure
217.5 psi
Start value for pressure measuring range
0 psi
Symbol
00995685
Approval
RCM trademark
c UL us listed (OL)
CE mark (see declaration of conformity)
To EU EMC Directive
In accordance with EU RoHS Directive
Certificate issuing authority
UL E322346
Note on materials
RoHS-compliant
Measured variable
Relative pressure
Measurement method
Piezoresistive pressure sensor
Start value for pressure measuring range
0 bar
End value for pressure measuring range
10 bar
Max. overload pressure
15 bar
Operating medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Inert gases
Note on operating and pilot medium
Lubricated operation possible
Temperature of medium
0 °C ... 50 °C
Ambient temperature
0 °C ... 50 °C
Accuracy in ± % FS
1.5 %FS
Repetition accuracy in ± %FS
0.3 %FS
Temperature coefficient in ± %FS/K
0.05 %FS/K
Switching output
2 x PNP or 2 x NPN, switchable
Switching function
Window comparator
Threshold value comparator
Auto difference monitoring
Switching element function
N/C or N/O contact, switchable
Max. output current
100 mA
Analogue output
0 - 10 V
4 - 20 mA
1 - 5 V
Max. load resistance current output
500 Ohm
Min. load resistance voltage output
20 kOhm
Short circuit current rating
yes
Protocol
IO-Link®
IO-Link, Protocol version
Device V 1.1
IO-Link, Profile
Smart sensor profile
IO-Link, Function classes
Binary data channel (BDC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link, communication mode
COM2 (38.4 kBaud)
IO-Link, SIO-Mode support
Yes
IO-Link, Port class
A
IO-Link, Process data length OUT
0 bytes
IO-Link, Process data length IN
2 bytes
IO-Link, Process data content IN
14 bit PDV (pressure measurement value)
2 bit BDC (pressure monitoring)
IO-Link, Min. cycle time
3 ms
IO-Link, Data storage required
500 Byte
Operational voltage range DC
15 V ... 30 V
Reverse polarity protection
For all electrical connections
Type of mounting
Front panel mounting
Via thread
Via wall/surface bracket
Mounting position
optional
Pneumatic connection
Female thread G1/8
Product weight
34 g
Material housing
PA-reinforced
Material in contact with the medium
FPM
Nickel-plated brass
NBR
PA-reinforced
Display type
Illuminated LCD
Displayable units
MPa
bar
inchH2O
inchHg
kPa
kgf/cm²
mbar
mmHg
psi
Setting options
IO-Link®
Teach-in
Via display and keys
Protection against tampering
IO-Link
PIN code
Setting range threshold value
0 % ... 100 %
Setting range hysteresis
0 % ... 90 %
Degree of protection
IP40
Corrosion resistance class CRC
2 - Moderate corrosion stress
Các sản phẩm cùng loại khác