LSRN-1 is a microwave water level gauge that determines water level based on the pulse propagation time. As this equipment uses microwave, it is not influenced by environmental conditions such as temperature, and can provide a atable measurement in rivers, etc.
Features
- ・Non-contact Measurement and Impervious to Driftwood and Sediment
- ・Accuracy is not Affected by Water and Ambient Temperature, Strong Wind
- ・Easy Installation and Maintenance
Available sites
- ・ River and Dam Water Level Monitoring
- ・ Control for Pomp Station, Water Gate
- ・ Torrential Debris Flow Monitoring
Main Specification
Equipment Configuration
|
Transducer, Junction-Box, Thermometer, Coder
|
Accuracy
|
±10mm(over 0.5m below mounting position of flange)
|
Measurement Range
|
0-10m(for river), 0-20m(for still-water level)
including dead band
|
Dead band |
within 0.5m below mounting position of flange |
Operational Temperature
|
Transducer: -20 to +70℃
|
Dimension
|
Transducer: W265xD265×H584mm
Coder: W96xH48xD124
|
Output of Coder |
Standard:Contact signal(when threshold over)
Option :4-20mA,BCD |
Function of Coder
|
Data display, Scale conversion, Level Offset, Averaging
|
Power Input
|
DC12V or AC90-220V
|