                        NL/NM/NNL/NNM/LS    Series 
                        A rorating paddle, being loaded by sediments in a  tank, activates a limit switch 
                        and brings contact output and motor roration to a  halt at the same time. | 
                    
                    
                        |   | 
                    
                    
                           Swing Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        SWM/SWG    Series 
                        There being no consumable part built in, it is                         nearly maintenance free. The 
                        pressure-proof construction improves sealing  performance to the extent of 
                        reducing troubles. | 
                    
                    
                        |   | 
                    
                    
                           Vibration Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KVK/KVA/KVS/KVF  Series 
                        Its capability of contamination resistance has  remarkably been upgraded in  
                        such a way that, because vibrating forks are  replaced with a straight rod, 
                        the surface area is changed to smaller. This  model is so unique that it may  
                        detect the low-density powders/solids over the  specific gravity of 0.03. | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KVX/XV2 Series 
                        Compact    & Highly Sensitive Vibration Level Switch 
                        Because the sensitivity is at the tip of the  sensing plate, it may not be  
                        affected by                         fouling or build-up at the plate-root. | 
                    
                    
                        |   | 
                    
                    
                           Capacitance Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    BLX Series 
                                    BLX detects an existence or no existence  of object in a vessel like silos or 
                                    tanks, depending on a capacitance  principle.                               The composition of the sensor 
                                    probe is  quite simple and rigid, which is made by stainless steel and some  insulators.                                | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                          | 
                        ALN/ SL Series 
                        It measures the capacitance variation arising in  between a main electrode 
                        and                         an earth electrode. 
                        The Model ALN can detect the level of sediments  in liquid and interface 
                        between two                         different liquids as well as the level from  high-insulating  
                        powders/solids to conductive liquids/viscous  liquids or the like.. | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    KCD Series 
                                    Multi-point Capacitance Type Level Switch                                  
                                    As opposed to a level switch whose  contact position is fixed, you can  
                                    arbitrarily change the alarm  position only with the zero/span check if the  
                                    contact position is within the measuring  range of the electrode.                                | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                           Float Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-200 Series 
                        Horizontal Float Switch 
                        The float switch can detect the varied liquid  levels in the form of altered  
                        'ON, OFF' of micro switch in that a magnet at  the other end of a float works 
                        magnetically and mutually with another magnet  in the terminal box  
                        completely blocked off by a septal wall | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-300 Series 
                        Vertical Float Switch 
                        The float switch housing a magnet inside a float  as well as a reed switch inside a stem, it is designed to have the reed  switch turn on or off with the built-in magnet which is subject to the  rise and fall of liquid level. 
                        Stoppers fixed on the upper and lower parts  limit the moving range of the  
                        float, thus marking the reed switch hold the  contact operation. | 
                    
                    
                        |   | 
                    
                    
                          | 
                        
                         Small Type Float Switch 
                        Ideal    for a small tank! 
                        Highly sophisticated model of compact float  switch applicable                         to multipurpose! 
                         | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-805N Series 
                        Multi-point Ball Float Switch 
                        A float gets tilt in a direction, and the  contact of a micro-switch built in the  
                        float is output. 
                        It reliably detects  levels of viscous liquids and wastewater containing suspended 
                        solids  including scum and so on. | 
                    
                    
                        |   | 
                    
                    
                           Microwave Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        MWS2-24TN/RN 
                        When a linear axis between the transmitter  and the receiver is interfered 
                        with an object to be measured, microwaves are  reflected and absorbed, thus 
                        making the receiver unable to receive them and  outputting the contact signals that the tank is full. | 
                    
                    
                        |   | 
                    
                    
                           Laser Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    TK-LASER 
                                    This is                                    a level switch utilizing laser as a  light source, consisting of two  
                                    facing                               units.  
                                    An object as distant as 20m can be  detected to the millimeter and yet with 
                                    pinpoint accuracy. | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                           Leak Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KEL-2 
                        It can detect an object to be measured from  resistance variation occurring 
                        between an electrode and the metal  tank-wall. 
                        It can be used for detection of all products  including sand as building materials,gravel, crushed rocks and so on as  long as they contain some moisture. | 
                    
                    
                        |   | 
                    
                    
                           Diaphragm Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-500 
                        As water level inside a tank rises, the pressure  inside the detection pipe gets 
                        higher. When the measuring face of  diaphragm gets pressure, the diaphragm 
                        pushes a micro switch to  provide a contact output. | 
                    
                    
                        |   | 
                    
                    
                           Tilt Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        TC-3/TC-1/PL  Series 
                        Rising materials contact the tilt switch, which  will make the body begin to 
                        tilt. When the body is tilted at 17°or more, a  metal ball housed in the switch 
                        rolls to switch the contact. | 
                    
                    
                        |   | 
                    
                    
                           Electrode Type Level Switch | 
                    
                    
                        |   | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-650/660N/677/688/KFB-640 
                        Assembled with an amplifier(acquired in the  market), it can detect the liquid 
                        level from with/without the minute  current in  conductive liquids flowing  
                        among                         electrodes. 
                        Liquid control, being made of varied electrode  materials,  can be applied to a 
                        variety of liquids. | 
                    
                    
                        |   | 
                    
                    
                        |  Level Meter | 
                    
                    
                        |   | 
                    
                    
                           Capacitance Type Level Indicator | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KLI/KLT/KLG  Series 
                        It continuously measures the capacitance  variation between the detection 
                        unit and the tank-wall. You are  offered a variety of sensors depending on the 
                        use conditions. 
                        (high temperature, high pressure, strong acid/  alkali, conductivity, insulation  
                        property,                          and others) | 
                    
                    
                        |   | 
                    
                    
                           Sounding(Bob) Type Level Indicator | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KSL Series 
                        When a start signal is input, the motor starts  up and then the metering tapes 
                        comes out,followed by the weight descending. 
                        The motor stops when the weight touches on the  measuring substance, and 
                        a level measurement is output. 
                        The motor reversely rotates to get the weight  back to the roll-up- 
                        complete position, and then stops. | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KSL-DS4 / DS8 
                        Microprocessor-control Controller 
                        Selecting a tank with One-touch Operation. 
                        The    descent distance of measuring tape/wire may be converted to the stock  
                        volume    in a tank. 
                        The measuring findings can be shown by  height(m), %, ton & m3. | 
                    
                    
                        |   | 
                    
                    
                           Float Type Level Indicator | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-100 Series 
                        Reed Switches and Resistors being built  in the stem, it can detect the varying  
                        liquid-level in the form of resistance changes  in that a magnet  in the float which 
                        is subject to being mobile depending on varied  liquid-level shuts a reed switch. 
                        The R/I-Converter can transmit this in the form  of DC 4-20mA current signals. | 
                    
                    
                        |   | 
                    
                    
                           Magnetostrictive(Dolphin Sensor)Type Level  Indicator | 
                    
                    
                        |   | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KF-900 Series 
                        Linear Displacement Sensor with magnetostrictive  wire inserted. It may  
                        detect at a magnetized spot supersonic vibration  transmitted through the 
                        magnetostrictive wire and output analogue  signals proportional to the position 
                        of the magnetized object. | 
                    
                    
                          | 
                    
                    
                           Ultrasonic Level Indicator | 
                    
                    
                        |   | 
                    
                    
                          | 
                        MINIFLEX/MULTIFLEX/REFLEX/SCANFLEX/MICROFLEX-C 
                        An ultrasonic pulse is emitted from the sensor  down                             towards an object and  
                        is reflected back from the surface. Its travel  time to/from the sensor, varied 
                        by the object increased or decreased,  can be measured by the unit which will 
                        then convert this variation to the form of  DC4-20mA signals to provide an 
                        output. | 
                    
                    
                        |   | 
                    
                    
                          | 
                        
                         LU20 Series 
                        Transmitter/Converter    in one unit. 
                        Measurable from the distance of 150mm.                          
                         | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    
                                     LU83 Series 
                                    Measurement    is least affected by any obstacles such as pipes and  
                                    instruments in  a tank.                                
                                    Two-Wire Ultrasonic Level Meter 
                                     | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    
                                     ENV100 
                                    Ultrasonic Sludge-blanket Level Meter 
                                    The automatic  cleaning system succeed in reducing a great deal of  
                                    maintenance  works. 
                                     | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                           Laser Type Level Indicator | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    LASER-RANG 
                                    Non-Contact Type level indicator utilizing  laser as a light source. 
                                    It is best suitable for non-contacting  measurement at the places where it  
                                    has been extremely difficult or dangerous   to measure with conventional 
                                    level meters. | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                           Radar Type Level Indicator | 
                    
                    
                        |   | 
                    
                    
                          | 
                        VF03 
                        Micro-impulse System 
                        As electromagnetic  pulses are emitted from the sensor down towards the  
                        probe, they  travel to the surface at a high speed by way of wire. Some pulses 
                        are reflected back to the sensor from the  surface.The unit calculates this  
                        travel time. | 
                    
                    
                        |   | 
                    
                    
                          | 
                        VG7 
                        FMCW(Frequency Modulated Continuous Wave) 
                        Micro pulses are continuously sent via an  antenna towards a product to be  
                        measured from which they are reflected back, It  calculate the round trip time from the frequency difference between  micro pulses emitted and those  
                        received at the antenna  to figure out the  level. | 
                    
                    
                         
                         | 
                    
                    
                        |  Conveyor Peripherals | 
                    
                    
                        |   | 
                    
                    
                           Conveyor Peripherals / Emergency Pull-wire  Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KP-850/860/870/880 
                        These switches, used for causing a belt-conveyor  to stop, are the best for  
                        the emergency stop. | 
                    
                    
                        |   | 
                    
                    
                           Conveyor Peripherals / Speed Detector | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KPS Series 
                        Reliably Catching Changes of Conveyor Speed! 
                        You can arbitrarily set up the operating speed  in the range of 3~1999 rpm. 
                        Accordingly it can widely be applied. | 
                    
                    
                        |   | 
                    
                    
                        |  Flow Sensor | 
                    
                    
                        |   | 
                    
                    
                           Flow Switch / Transit Alarm | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KP-4/810/820/830,  KPG-840 
                        You may install the unit in such a way that the  sensing plate may be located at a  
                        conveyor chute outlet where products are being  carried over/run through, and it will 
                        detect the presence of passing products. 
                        You can change the torque and the sensing angle  depending on the nature of the  
                        passing products.                         (except KP-4 and KPG-840) | 
                    
                    
                        |   | 
                    
                    
                           Microwave Type Flow Sensor | 
                    
                    
                        |   | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KFD-1 
                        The microwaves emitted from the tip of its  sensor are reflected from the  
                        surface of powders/solids  traveling in a  pipeline, and the reflected waves will 
                        get modulated in their  frequency on the Doppler Effect principle.                          
                        The sensor, detecting the frequency  difference between transmitted and  
                        reflected microwaves, transforms/amplifies it to   output contact signals. | 
                    
                    
                        |   | 
                    
                    
                           Particle Flow Switch | 
                    
                    
                        |   | 
                    
                    
                          | 
                        KDS-1 
                        It can detect the density of minute particles  through an electrode fixed on  
                        duct                         or pipe. It is the sensor measuring the electric  charge of minute  
                        particles. When the density reaches the preset  values, it outputs the contact externally. | 
                    
                    
                        |   | 
                    
                    
                        |  Dust Monitor | 
                    
                    
                        |   | 
                    
                    
                           Electrodynamic Dust Emissions Monitor | 
                    
                    
                        |   | 
                    
                    
                          | 
                        DT370/DX800/DT990/DA50 
                        By applying the TriboACE measurement principle,  it detects the charge  
                        movement of  particles traveling in a duct. The  unit, measuring the charge movement signals, will convert to an a.c.  response. Tribo-electric 
                        current generated when particles collide  directly with the probe will be  
                        trimmed through a special circuit in order to  ensure reliable outputs. | 
                    
                    
                        |   | 
                    
                    
                           Scintillation Type Dust Emissions Monitor | 
                    
                    
                        |   | 
                    
                    
                          | 
                        SC602 
                        The unit monitors the variation of a light beam  across the stack and  
                        calculates the amount of received light and the  ratio of light variation 
                        (scintillation). The added benefit is that it is  capable of measuring in face of 
                        lens contamination because, when the lens  fouling decreases the amount  
                        of received light, scintillation also  decreases proportionately to the varied  
                        light amount. | 
                    
                    
                        |   | 
                    
                    
                        |  Oxygen Analyzer | 
                    
                    
                        |   | 
                    
                    
                           Oxygen Analyzer | 
                    
                    
                        |   | 
                    
                    
                          | 
                        OXITEC 5000 
                        Zirconia Oxygen Analyzing System 
                        The special sealing technique has ensured highly  reliable measurement. | 
                    
                    
                        |   | 
                    
                    
                        |  Fluid Analyzer | 
                    
                    
                        |   | 
                    
                    
                           Fluid Analyzer | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    Fluid Scan 
                                    Online    Fluid Analyzing Sensor 
                                    Available are sensors for Liquid  Concentration/Turbidity Measurement, Mixture 
                                    Ratio Measurement,  Content Quality Monitoring and Fat Content Measurement. | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                        |  Gas Analyzer | 
                    
                    
                        |   | 
                    
                    
                           Gas Analyzer | 
                    
                    
                        |   | 
                    
                    
                          | 
                        GASMET 
                        CEMS  System 
                        Gas Analyzer adopting the FTIR theory can  measure many different gas  
                        compounds. It can simultaneously measure up to  50 different mixed gases 
                        from low(ppm) to high(%) concentration. | 
                    
                    
                        |   | 
                    
                    
                        |  Liquid Flow Sensor | 
                    
                    
                        |   | 
                    
                    
                           Ultrasonic Liquid Flowmeter | 
                    
                    
                        |   | 
                    
                    
                          | 
                        MICRONICS  
                        Clamp-on Non-invasive Sensing Solution 
                        It measures a Transit Time ultrasonic flow. It  can accurately measure with 
                        clamp-on transducers without the need for any  mechanical parts to be inserted into the pipe or to be protruded  therein. | 
                    
                    
                        |   | 
                    
                    
                        
                        
                            
                                
                                      | 
                                    AVFM-II  Submersible Type 
                                    After mounting a sensor on the  bottom of a channel without a flume or weir, 
                                    you can measure the flow volume only by  entering the pipe diameter or  
                                    channel width. It can measure the  actual flow velocity and water-level in a  
                                    real time.                                  
                                     | 
                                 
                            
                         
                         | 
                    
                    
                        |   | 
                    
                    
                        |  Powder Flow Sensor | 
                    
                    
                        |   | 
                    
                    
                           Powder Flow Sensor | 
                    
                    
                        |   | 
                    
                    
                          | 
                        FM60 
                        Electrodynamic Technology 
                        Solids Flow  Mounting System 
                        Significant Resolution, Easy Operation!! |