|  | NL/NM/NNL/NNM/LS    Series A rorating paddle, being loaded by sediments in a  tank, activates a limit switch
 and brings contact output and motor roration to a  halt at the same time.
 | 
                    
                        |  | 
                    
                        |  Swing Type Level Switch | 
                    
                        |  | 
                    
                        |  | SWM/SWG    Series There being no consumable part built in, it is                         nearly maintenance free. The
 pressure-proof construction improves sealing  performance to the extent of
 reducing troubles.
 | 
                    
                        |  | 
                    
                        |  Vibration Type Level Switch | 
                    
                        |  | 
                    
                        |  | KVK/KVA/KVS/KVF  Series Its capability of contamination resistance has  remarkably been upgraded in
 such a way that, because vibrating forks are  replaced with a straight rod,
 the surface area is changed to smaller. This  model is so unique that it may
 detect the low-density powders/solids over the  specific gravity of 0.03.
 | 
                    
                        |  | 
                    
                        |  | KVX/XV2 Series Compact    & Highly Sensitive Vibration Level Switch
 Because the sensitivity is at the tip of the  sensing plate, it may not be
 affected by                         fouling or build-up at the plate-root.
 | 
                    
                        |  | 
                    
                        |  Capacitance Type Level Switch | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | BLX Series BLX detects an existence or no existence  of object in a vessel like silos or
 tanks, depending on a capacitance  principle.                               The composition of the sensor
 probe is  quite simple and rigid, which is made by stainless steel and some  insulators.
 |  | 
                    
                        |  | 
                    
                        |  | ALN/ SL Series It measures the capacitance variation arising in  between a main electrode
 and                         an earth electrode.
 The Model ALN can detect the level of sediments  in liquid and interface
 between two                         different liquids as well as the level from  high-insulating
 powders/solids to conductive liquids/viscous  liquids or the like..
 | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | KCD Series Multi-point Capacitance Type Level Switch
 As opposed to a level switch whose  contact position is fixed, you can
 arbitrarily change the alarm  position only with the zero/span check if the
 contact position is within the measuring  range of the electrode.
 |  | 
                    
                        |  | 
                    
                        |  Float Type Level Switch | 
                    
                        |  | 
                    
                        |  | KF-200 Series Horizontal Float Switch
 The float switch can detect the varied liquid  levels in the form of altered
 'ON, OFF' of micro switch in that a magnet at  the other end of a float works
 magnetically and mutually with another magnet  in the terminal box
 completely blocked off by a septal wall
 | 
                    
                        |  | 
                    
                        |  | KF-300 Series Vertical Float Switch
 The float switch housing a magnet inside a float  as well as a reed switch inside a stem, it is designed to have the reed  switch turn on or off with the built-in magnet which is subject to the  rise and fall of liquid level.
 Stoppers fixed on the upper and lower parts  limit the moving range of the
 float, thus marking the reed switch hold the  contact operation.
 | 
                    
                        |  | 
                    
                        |  | Small Type Float SwitchIdeal    for a small tank!
 Highly sophisticated model of compact float  switch applicable                         to multipurpose!
 | 
                    
                        |  | 
                    
                        |  | KF-805N Series Multi-point Ball Float Switch
 A float gets tilt in a direction, and the  contact of a micro-switch built in the
 float is output.
 It reliably detects  levels of viscous liquids and wastewater containing suspended
 solids  including scum and so on.
 | 
                    
                        |  | 
                    
                        |  Microwave Type Level Switch | 
                    
                        |  | 
                    
                        |  | MWS2-24TN/RN When a linear axis between the transmitter  and the receiver is interfered
 with an object to be measured, microwaves are  reflected and absorbed, thus
 making the receiver unable to receive them and  outputting the contact signals that the tank is full.
 | 
                    
                        |  | 
                    
                        |  Laser Type Level Switch | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | TK-LASER This is                                    a level switch utilizing laser as a  light source, consisting of two
 facing                               units.
 An object as distant as 20m can be  detected to the millimeter and yet with
 pinpoint accuracy.
 |  | 
                    
                        |  | 
                    
                        |  Leak Type Level Switch | 
                    
                        |  | 
                    
                        |  | KEL-2 It can detect an object to be measured from  resistance variation occurring
 between an electrode and the metal  tank-wall.
 It can be used for detection of all products  including sand as building materials,gravel, crushed rocks and so on as  long as they contain some moisture.
 | 
                    
                        |  | 
                    
                        |  Diaphragm Type Level Switch | 
                    
                        |  | 
                    
                        |  | 
                    
                        |  | KF-500 As water level inside a tank rises, the pressure  inside the detection pipe gets
 higher. When the measuring face of  diaphragm gets pressure, the diaphragm
 pushes a micro switch to  provide a contact output.
 | 
                    
                        |  | 
                    
                        |  Tilt Type Level Switch | 
                    
                        |  | 
                    
                        |  | TC-3/TC-1/PL  Series Rising materials contact the tilt switch, which  will make the body begin to
 tilt. When the body is tilted at 17°or more, a  metal ball housed in the switch
 rolls to switch the contact.
 | 
                    
                        |  | 
                    
                        |  Electrode Type Level Switch | 
                    
                        |  | 
                    
                        |  | 
                    
                        |  | KF-650/660N/677/688/KFB-640 Assembled with an amplifier(acquired in the  market), it can detect the liquid
 level from with/without the minute  current in  conductive liquids flowing
 among                         electrodes.
 Liquid control, being made of varied electrode  materials,  can be applied to a
 variety of liquids.
 | 
                    
                        |  | 
                    
                        | Level Meter | 
                    
                        |  | 
                    
                        |  Capacitance Type Level Indicator | 
                    
                        |  | 
                    
                        |  | KLI/KLT/KLG  Series It continuously measures the capacitance  variation between the detection
 unit and the tank-wall. You are  offered a variety of sensors depending on the
 use conditions.
 (high temperature, high pressure, strong acid/  alkali, conductivity, insulation
 property,                          and others)
 | 
                    
                        |  | 
                    
                        |  Sounding(Bob) Type Level Indicator | 
                    
                        |  | 
                    
                        |  | KSL Series When a start signal is input, the motor starts  up and then the metering tapes
 comes out,followed by the weight descending.
 The motor stops when the weight touches on the  measuring substance, and
 a level measurement is output.
 The motor reversely rotates to get the weight  back to the roll-up-
 complete position, and then stops.
 | 
                    
                        |  | 
                    
                        |  | KSL-DS4 / DS8 Microprocessor-control Controller
 Selecting a tank with One-touch Operation.
 The    descent distance of measuring tape/wire may be converted to the stock
 volume    in a tank.
 The measuring findings can be shown by  height(m), %, ton & m3.
 | 
                    
                        |  | 
                    
                        |  Float Type Level Indicator | 
                    
                        |  | 
                    
                        |  | KF-100 Series Reed Switches and Resistors being built  in the stem, it can detect the varying
 liquid-level in the form of resistance changes  in that a magnet  in the float which
 is subject to being mobile depending on varied  liquid-level shuts a reed switch.
 The R/I-Converter can transmit this in the form  of DC 4-20mA current signals.
 | 
                    
                        |  | 
                    
                        |  Magnetostrictive(Dolphin Sensor)Type Level  Indicator | 
                    
                        |  | 
                    
                        |  | 
                    
                        |  | KF-900 Series Linear Displacement Sensor with magnetostrictive  wire inserted. It may
 detect at a magnetized spot supersonic vibration  transmitted through the
 magnetostrictive wire and output analogue  signals proportional to the position
 of the magnetized object.
 | 
                    
                        |  | 
                    
                        |  Ultrasonic Level Indicator | 
                    
                        |  | 
                    
                        |  | MINIFLEX/MULTIFLEX/REFLEX/SCANFLEX/MICROFLEX-C An ultrasonic pulse is emitted from the sensor  down                             towards an object and
 is reflected back from the surface. Its travel  time to/from the sensor, varied
 by the object increased or decreased,  can be measured by the unit which will
 then convert this variation to the form of  DC4-20mA signals to provide an
 output.
 | 
                    
                        |  | 
                    
                        |  | LU20 SeriesTransmitter/Converter    in one unit.
 Measurable from the distance of 150mm.
 | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | LU83 SeriesMeasurement    is least affected by any obstacles such as pipes and
 instruments in  a tank.
 Two-Wire Ultrasonic Level Meter
 |  | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | ENV100Ultrasonic Sludge-blanket Level Meter
 The automatic  cleaning system succeed in reducing a great deal of
 maintenance  works.
 |  | 
                    
                        |  | 
                    
                        |  Laser Type Level Indicator | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | LASER-RANG Non-Contact Type level indicator utilizing  laser as a light source.
 It is best suitable for non-contacting  measurement at the places where it
 has been extremely difficult or dangerous   to measure with conventional
 level meters.
 |  | 
                    
                        |  | 
                    
                        |  Radar Type Level Indicator | 
                    
                        |  | 
                    
                        |  | VF03 Micro-impulse System
 As electromagnetic  pulses are emitted from the sensor down towards the
 probe, they  travel to the surface at a high speed by way of wire. Some pulses
 are reflected back to the sensor from the  surface.The unit calculates this
 travel time.
 | 
                    
                        |  | 
                    
                        |  | VG7 FMCW(Frequency Modulated Continuous Wave)
 Micro pulses are continuously sent via an  antenna towards a product to be
 measured from which they are reflected back, It  calculate the round trip time from the frequency difference between  micro pulses emitted and those
 received at the antenna  to figure out the  level.
 | 
                    
                        | 
 | 
                    
                        | Conveyor Peripherals | 
                    
                        |  | 
                    
                        |  Conveyor Peripherals / Emergency Pull-wire  Switch | 
                    
                        |  | 
                    
                        |  | KP-850/860/870/880 These switches, used for causing a belt-conveyor  to stop, are the best for
 the emergency stop.
 | 
                    
                        |  | 
                    
                        |  Conveyor Peripherals / Speed Detector | 
                    
                        |  | 
                    
                        |  | KPS Series Reliably Catching Changes of Conveyor Speed!
 You can arbitrarily set up the operating speed  in the range of 3~1999 rpm.
 Accordingly it can widely be applied.
 | 
                    
                        |  | 
                    
                        | Flow Sensor | 
                    
                        |  | 
                    
                        |  Flow Switch / Transit Alarm | 
                    
                        |  | 
                    
                        |  | KP-4/810/820/830,  KPG-840 You may install the unit in such a way that the  sensing plate may be located at a
 conveyor chute outlet where products are being  carried over/run through, and it will
 detect the presence of passing products.
 You can change the torque and the sensing angle  depending on the nature of the
 passing products.                         (except KP-4 and KPG-840)
 | 
                    
                        |  | 
                    
                        |  Microwave Type Flow Sensor | 
                    
                        |  | 
                    
                        |  | 
                    
                        |  | KFD-1 The microwaves emitted from the tip of its  sensor are reflected from the
 surface of powders/solids  traveling in a  pipeline, and the reflected waves will
 get modulated in their  frequency on the Doppler Effect principle.
 The sensor, detecting the frequency  difference between transmitted and
 reflected microwaves, transforms/amplifies it to   output contact signals.
 | 
                    
                        |  | 
                    
                        |  Particle Flow Switch | 
                    
                        |  | 
                    
                        |  | KDS-1 It can detect the density of minute particles  through an electrode fixed on
 duct                         or pipe. It is the sensor measuring the electric  charge of minute
 particles. When the density reaches the preset  values, it outputs the contact externally.
 | 
                    
                        |  | 
                    
                        | Dust Monitor | 
                    
                        |  | 
                    
                        |  Electrodynamic Dust Emissions Monitor | 
                    
                        |  | 
                    
                        |  | DT370/DX800/DT990/DA50 By applying the TriboACE measurement principle,  it detects the charge
 movement of  particles traveling in a duct. The  unit, measuring the charge movement signals, will convert to an a.c.  response. Tribo-electric
 current generated when particles collide  directly with the probe will be
 trimmed through a special circuit in order to  ensure reliable outputs.
 | 
                    
                        |  | 
                    
                        |  Scintillation Type Dust Emissions Monitor | 
                    
                        |  | 
                    
                        |  | SC602 The unit monitors the variation of a light beam  across the stack and
 calculates the amount of received light and the  ratio of light variation
 (scintillation). The added benefit is that it is  capable of measuring in face of
 lens contamination because, when the lens  fouling decreases the amount
 of received light, scintillation also  decreases proportionately to the varied
 light amount.
 | 
                    
                        |  | 
                    
                        | Oxygen Analyzer | 
                    
                        |  | 
                    
                        |  Oxygen Analyzer | 
                    
                        |  | 
                    
                        |  | OXITEC 5000 Zirconia Oxygen Analyzing System
 The special sealing technique has ensured highly  reliable measurement.
 | 
                    
                        |  | 
                    
                        | Fluid Analyzer | 
                    
                        |  | 
                    
                        |  Fluid Analyzer | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | Fluid Scan Online    Fluid Analyzing Sensor
 Available are sensors for Liquid  Concentration/Turbidity Measurement, Mixture
 Ratio Measurement,  Content Quality Monitoring and Fat Content Measurement.
 |  | 
                    
                        |  | 
                    
                        | Gas Analyzer | 
                    
                        |  | 
                    
                        |  Gas Analyzer | 
                    
                        |  | 
                    
                        |  | GASMET CEMS  System
 Gas Analyzer adopting the FTIR theory can  measure many different gas
 compounds. It can simultaneously measure up to  50 different mixed gases
 from low(ppm) to high(%) concentration.
 | 
                    
                        |  | 
                    
                        | Liquid Flow Sensor | 
                    
                        |  | 
                    
                        |  Ultrasonic Liquid Flowmeter | 
                    
                        |  | 
                    
                        |  | MICRONICS Clamp-on Non-invasive Sensing Solution
 It measures a Transit Time ultrasonic flow. It  can accurately measure with
 clamp-on transducers without the need for any  mechanical parts to be inserted into the pipe or to be protruded  therein.
 | 
                    
                        |  | 
                    
                        | 
                            
                                
                                    |  | AVFM-II  Submersible Type After mounting a sensor on the  bottom of a channel without a flume or weir,
 you can measure the flow volume only by  entering the pipe diameter or
 channel width. It can measure the  actual flow velocity and water-level in a
 real time.
 
 |  | 
                    
                        |  | 
                    
                        | Powder Flow Sensor | 
                    
                        |  | 
                    
                        |  Powder Flow Sensor | 
                    
                        |  | 
                    
                        |  | FM60 Electrodynamic Technology
 Solids Flow  Mounting System
 Significant Resolution, Easy Operation!!
 |