Aschcroft |
Temperature gauge |
Range 0-100degC. Stem threaded: 1/2". Stem diameter 1/4". Steam length: 12". Gauge diameter 5" Form: adiustable |
50EI60E120 0/100C |
Aschcroft |
Temperature gauge |
Range 0-100degC. Stem threaded: 1/2". Stem diameter 1/4". Steam length: 14". Gauge diameter 5". Form: adjustable. |
50E160E140 0/100C |
Aschcroft |
Temperature gauge |
Range 0-200degC. Stem threaded: 1/2". Stem diameter 1/4". Steam length: 14". Gauge diameter 5". Form: adjustable. |
50EI60E140 0/200C |
Aschcroft |
Temperature gauge |
Range 0-250degC. Stem threaded: 1/2". Stem diameter 1/4". Steam length: 18". Gauge diameter 5". Form: adjustable. |
50EI60E180 0/250C |
Aschcroft |
Pressure switch |
0-200 PSIG. NEMA 4X, DPDT, VITON SEAL |
B-4-64-V-200PSI-UL-06 |
Aschcroft |
Temperature switch |
651125 degC |
T7-24- T1 0-030-651125-UL-BX-K3-FS |
Aschcroft |
Pressure Gauge |
0-25000KPA |
45-1279-SSL-04L-XSG |
Aschcroft |
Pressure Gauge |
0-10000KPA |
45-1279-SSL-04L-XSG |
Aschcroft |
Pressure switch |
0-100Psig. |
B7 68 S 100 PSI CEN4 06 |
Asco |
Solenoid valve |
Manual ResettinK Valve |
NBB307C008UMO |
Ascon |
Temperature Switch |
for Common Heater Panel in SWGR, Model: MS- 30/ABA, Conf.: 9999, Power: 100/240 VAC, Serial N: 9612/1019 |
035575-3 |
Barksdale Raychem |
Temperature Switch |
(-)4 to 163°C |
TXR-L2S-10-Q10 |
Bently Nevada |
Four chanel monitor module |
2201 monitoring system. 0.7 Amps BNC Solar P1N190662-23 ( or -24, -26, -28 ?) |
102577-01 |
Bently Nevada |
System vibration monitor module |
2201 monitoring system. 1.0 Amps BNC Firmware revision J (Solar PIN190662-11) |
127234-01 |
Bently Nevada |
Vibration promitor |
3300XL 11mm |
330780-50-05 |
Bently Nevada |
Vibration probe 3300XL |
|
330704-00-050-10-02-05 |
Bently Nevada |
Dual vibration monitor Xygap |
|
3300/16-XX-03-03-00-0 1-00 |
Bently Nevada |
Proximitor |
Mod 154708-01 (Solar P/N 120662-18), scale factor 25mV/G |
49578-01 |
Bently Nevada |
Vibration Probe 3300 XL |
Cable resistance 95Ohm. Cable length 1m. Tip material polyphenylene supplied. Tip diameter 0.3'' (8mm), thread size 3/8-24 probe length - 50mm connector type - standards |
330102-00-20-10-02-05 |
Bently Nevada |
Probe 5-Meter system, 7200 series 95 Ohm |
Cable length 1m. Cable resistance 95 Ohm. Tip material polyphenylene suplide. Tip diameter 0.3" (8 mm), thread size 3/8"-24 |
102048-00-48-10-02 |
Bently Nevada |
Vibration Probe 3300 XL |
Cable resistance 95 Ohm. Cabellength 1m. Tip material polyphenylene suplide. Tip diameter 0.3" (8 mm), thread size 3/8"-24 probe lenght - 125 mm connector type - standard |
3301 02-00-50-10-02-05 |
Bently Nevada |
Vibration proximitor |
|
330180-50-05 |
Bifold, England |
Air Regulator |
All stainless steel, S/S Combined Filter Regulator. Max in: 10/16 bar Max out: 0/10 bar |
SH06-FR-SR-MD-10X1X8 |
Burkert, Germany |
Solenoid |
24VDC, 2-8BAR |
F791B024UXD19N00 |
CARLO GAVAZZI |
Limit swich Angle |
40mm (fix 30mm). One-cable inlet 1/2" NPT. Snap 1N |
PS31L-NPS11LS-M00 PS |
Crouzet |
Relay |
Normally-Open Panel-Mount Solid-State |
84134900 |
Delta Controls |
Pressure switch |
15 to 75 Bar |
RS245SEF03H02 |
Delta Controls |
Pressure switch |
2,5 To 25 Bar |
RS245SV703H02 |
Delta Controls |
Pressure switch |
ZONE 1 ATEX For Aggressive Atmospheres Eexd, IIC T6( -60 toe +65 C) T5 (-60 to+80 C) Investment cast enclosure in austenitic stainless steel certified to CENELEC EN 50, 014 and EN50 018, Weatherproof to NEMA type 4X, IP66- Electrical entry: M20 x 1.5 Dual Entry, Material of wetted parts: 316 stainless steel diaphragm, process connection and Viton O-ring seal., Pmax: 600 bar, Range: 10-100 bar, Switch option: 2 Amps @ 30V DC, 2 switch with NO, NC., Process connection: 1/2 NPT INT, Option and treatment: Marine and Offshore Saline atmosphere or salt spray |
RS245SFA03H02 |
Delta Controls |
Pressure switch |
ZONE 1 ATEX For Aggressive Atmospheres Eexd, IIC T6( -60 toe +65 C) T5 (-60 to+80 C) Investment cast enclosure in austenitic stainless steel certified to CENELEC EN 50, 014 and EN50 018, Weatherproof to NEMA type 4X, IP66- Electrical entry: M20 x 1.5 Dual Entry, Material of wetted parts: 316 stainless steel diaphragm, process connection and Viton O-ring seal., Pmax: 600 bar, Range: 10-100 bar, Switch option: 2 Amps @ 30V DC, 2 switch with NO, NC., Process connection: 1/2 NPT INT, Option and treatment: Marine and Offshore Saline atmosphere or salt spray |
RS245SEA03H02 |
Dettronics |
IR fire detector |
4-20 ma output |
X9800S4N13W2 |
ETTORE CELLA |
Temp. Switch |
40/100 DEGC |
TCA4CB |
Flowserve |
Digital positioner |
LOGIX 500MD (for LV 6104, PV 6901, PV 7101) |
520MD-15- Y1DEE-0000-000 |
Honeywell Analytics/ Sieger |
SensePoint Combutible Gas Sensor |
Range 0-100% LEL, DE1155 ATEX approved |
2106B1201 |
Ingersoll Rand Sierr A |
Pressure transmitter |
for air Dryer HLI000. Range 0-225 Psi. (Package Discharge) Ref.No. M1208 0191 |
39875539 |
Ingersoll Rand Sierr A |
Temperature sensor |
Range 0-510 oF |
39568092 |
Kentintrol |
Electro/ Pneumatic Valve Positioner |
Model WEP P3300i series Input signal 0.2-1 barg, action direct. Explosion proof certified |
P3300i/2 |
Krohne |
Flow Indicating transmitter |
Calibrated Range 0.4-4 Nm3/hr. Accuracy class 1.6. Out4-20mA. Sensor pipe & Flange sizes likes for Flowmeter SN: 7/132833.001 |
H250/RR/M10-Eex |
Littlefuse |
Fuse |
5x20 mm. 5A, 30 VDC |
216.005.P |
Littlefuse |
Fuse |
4A 30 VDC, length: 20mm, dia: 5mm |
216.004.P . |
Littlefuse |
Fuse |
8A 30 VDC, length: 20mm, dia: 5mm |
216.008.P |
Magnetrol |
Switch mechanism |
Level Switch |
059549-001 |
Magnetrol |
Housing Kit |
(Levvel Switches on 1-V-252/253) |
05949-002 |
MarkLoad |
PCB for crane loadcell |
PCB for loadcelll |
F4030-C0l |
MarkLoad |
Loadcell |
On the body: 2701-001-Ex |
F5080-M41P |
McDaniel |
Pressure Indicator |
0- 3000 psi |
Q3NGF |
McDaniel |
Pressure Indicator |
1 - 200 psi |
Q3FGF |
MEDC PINXTON |
ESD Beacon |
|
SM87HXBS024RY1NNR |
MEDC PINXTON |
APS beacon |
|
SM87HXBS024 BY1NNB |
MTL Instruments Pvt |
Shunt-diode Safety Barrier |
|
MTL728+ |