GNN AQUARIAN PRODUCT COMPARISON GUIDE
-- 5/27/2015
GNN AQUARIAN PRODUCT COMPARISON GUIDE
AQUARIAN PRODUCT COMPARISON GUIDE |
|
Aquarian |
Aquarian |
Aquarian |
Aquarian |
|
Alarm Module |
1000 Plus |
3000 M |
3000 Plus |
System |
• 120 VAC 1/4 Amp |
• 120 VAC 1/4 Amp |
• 120 VAC 1/2 Amp |
• 120 VAC 1/2 Amp |
Specifications |
• 240 VAC 1/4 Amp |
• 240 VAC 1/8 Amp |
• 240 VAC 1/4 Amp |
• 240 VAC 1/4 Amp |
|
• 50/60 HZ |
• 50/60 HZ |
• 50/60 HZ |
• 50/60 HZ |
|
|
• Redundant Power |
• Redundant Power |
• Redundant Power Supplies |
|
|
|
|
• Dual Power Supplies |
|
• Single Probe |
• 4 Probe |
• 12 Probe |
• 14 Probe |
|
|
• Nema 4X Cubicle |
• Nema 4X Cubicle |
• Nema 4X Cubicle |
|
|
|
• Remote Display capability |
• Remote Display capability |
|
|
|
• Local Display capability |
• Local Display capability |
|
System |
|
• Power Supply PS1 |
• Power Supply PS1 |
• Power Supply PS1 |
Diagnostics |
|
• Power Supply PS2 |
• Power Supply PS2 |
• Power Supply PS2 |
|
|
• Detection Clock |
• Detection Clock |
• Detection Clock |
|
|
• Level Fault |
• Level Fault |
|
|
|
• Probe Continuity (Option) |
• Probe Continuity (Option) |
• Probe Continuity (Option) |
|
|
• Probe Short Circuit (Option) |
|
• Probe Short Circuit (Option) |
|
Level Contact |
• Single relay |
• One relay per level |
• One relay per level |
• Six relays |
Outputs |
• Two Form-C |
• Two Form-A |
• Form-C |
• Form-C |
|
• Energized or De-Energized |
• or a Form-A and Form-B |
• Energized on Water |
• Energized or De-Energized |
|
on Water |
• Energized or De-Energized |
|
on Water |
|
|
on Water |
|
• Selectable to any level |
|
High Level |
|
• Using level relay output |
• Using level relay output |
• Dedicated relay output |
Alarm |
|
|
|
• Form-C |
|
|
|
|
• Energized or De-Energized |
|
|
|
|
on Trip |
|
|
|
|
• Up to four probe levels |
|
|
|
|
• One or two vote operation |
|
Low Level |
|
• Using level relay output |
• Using level relay output |
• Dedicated relay output |
Alarm |
|
|
|
• Form-C |
|
|
|
|
• Energized or De-Energized |
|
|
|
|
on Trip |
|
|
|
|
• Up to four probe levels |
|
|
|
|
• One or two vote operation |
|
Column |
• 1/2" Type A Connector |
• 2000 psi Stainless |
• 650 psi Carbon |
• 2000 psi Stainless |
Availability |
• 1 1/2" Connector |
• 3000 psi Stainless |
• 2000 psi Stainless |
• 3000 psi Stainless |
|
|
• 1/2" Type A Connector |
• 3000 psi Stainless |
|
|
|
• 1 1/2" Connector |
|
|
|
|
|
• High Pressure Probe |
• High Pressure Probe |
|
|
|
• Low Pressure Probe |
• Low Pressure Probe |
|
Conductivity |
• >200 ụmhos |
• >25 ụmhos |
• >25 ụmhos |
• >25 ụmhos |
Range |
• >100 ụmhos |
• >4 ụmhos |
• >4 ụmhos |
• >4 ụmhos |
|
• >50 ụmhos |
• >0.5 ụmhos |
• >0.5 ụmhos |
• >0.5 ụmhos |
|
• >5 ụmhos |
|
|
|
|
Level Tracking |
|
|
• Isolated |
• Isolated |
4-20 mA Module |
|
|
• Int/Ext Loop Supply |
• Int/Ext Loop Supply |
Option |
|
|
• 4-20 mA, 0-20 mA |
• 4-20 mA, 0-20 mA |
|
|
|
• 1-5 VDC, 0-5VDC |
• 1-5 VDC, 0-5VDC |
|
|
|
• Works with up to 48 Probes |
• 14 Probe opertion • Requires Processor Module |
|
Processor |
|
|
|
• Flashing Level Fault |
Module |
|
|
|
• Flashing Hi/Lo Alarms |
Option |
|
|
|
• Additional Alarm Relay |
|
|
|
|
• 4-20 mA Module |
|
|
|
|
• 5-Wire Serial link to |
|
|
|
|
Remote Display |
Số người xem :