PERFECT AUTOMATION SOLUTION
English Japan
GNN AQUARIAN PRODUCT COMPARISON GUIDE

GNN AQUARIAN PRODUCT COMPARISON GUIDE


  --  5/27/2015
GNN AQUARIAN PRODUCT COMPARISON GUIDE
AQUARIAN PRODUCT COMPARISON GUIDE
  Aquarian Aquarian Aquarian Aquarian
             Alarm Module 1000 Plus 3000 M 3000 Plus
System • 120 VAC 1/4 Amp • 120 VAC 1/4 Amp • 120 VAC 1/2 Amp • 120 VAC 1/2 Amp
Specifications • 240 VAC 1/4 Amp • 240 VAC 1/8 Amp • 240 VAC 1/4 Amp • 240 VAC 1/4 Amp
  • 50/60 HZ • 50/60 HZ • 50/60 HZ • 50/60 HZ
    • Redundant Power • Redundant Power • Redundant Power Supplies
        • Dual Power Supplies
  • Single Probe • 4 Probe • 12 Probe • 14 Probe
    • Nema 4X Cubicle • Nema 4X Cubicle • Nema 4X Cubicle
      • Remote Display capability • Remote Display capability
      • Local Display capability • Local Display capability
 
System   • Power Supply PS1 • Power Supply PS1 • Power Supply PS1
Diagnostics   • Power Supply PS2 • Power Supply PS2 • Power Supply PS2
    • Detection Clock • Detection Clock • Detection Clock
    • Level Fault • Level Fault  
    • Probe Continuity (Option) • Probe Continuity (Option) • Probe Continuity (Option)
    • Probe Short Circuit (Option)   • Probe Short Circuit (Option)
 
Level Contact • Single relay • One relay per level • One relay per level • Six relays
Outputs • Two Form-C • Two Form-A • Form-C • Form-C
  • Energized or De-Energized • or a Form-A and Form-B • Energized on Water • Energized or De-Energized
  on Water • Energized or De-Energized   on Water
    on Water   • Selectable to any level
 
High Level   • Using level relay output • Using level relay output • Dedicated relay output
Alarm       • Form-C
        • Energized or De-Energized
        on Trip
        • Up to four probe levels
        • One or two vote operation
 
Low Level   • Using level relay output • Using level relay output • Dedicated relay output
Alarm       • Form-C
        • Energized or De-Energized
        on Trip
        • Up to four probe levels
        • One or two vote operation
 
Column • 1/2" Type A Connector • 2000 psi Stainless • 650 psi Carbon • 2000 psi Stainless
Availability • 1 1/2" Connector • 3000 psi Stainless • 2000 psi Stainless • 3000 psi Stainless
    • 1/2" Type A Connector • 3000 psi Stainless  
    • 1 1/2" Connector    
      • High Pressure Probe • High Pressure Probe
      • Low Pressure Probe • Low Pressure Probe
 
Conductivity • >200 ụmhos • >25 ụmhos • >25 ụmhos • >25 ụmhos
Range • >100 ụmhos • >4 ụmhos • >4 ụmhos • >4 ụmhos
  • >50 ụmhos • >0.5 ụmhos • >0.5 ụmhos • >0.5 ụmhos
  • >5 ụmhos      
     
Level Tracking     • Isolated • Isolated
4-20 mA Module     • Int/Ext Loop Supply • Int/Ext Loop Supply
Option     • 4-20 mA, 0-20 mA • 4-20 mA, 0-20 mA
      • 1-5 VDC, 0-5VDC • 1-5 VDC, 0-5VDC
      • Works with up to 48 Probes •    14 Probe opertion •    Requires Processor Module
 
Processor       • Flashing Level Fault
Module       • Flashing Hi/Lo Alarms
Option       • Additional Alarm Relay
        • 4-20 mA Module
        • 5-Wire Serial link to
        Remote Display

 

Số người xem : 6296