Shipping date |
View |
Dimensions W x L x H |
40 mm x 91 mm x 50 mm |
Grid dimension |
40 mm |
Mounting type |
On electrical interface
On electrical connection block |
Product weight |
93 g |
Protocol |
PROFINET |
Fieldbus interface |
Ethernet |
Fieldbus interface, protocol |
PROFINET RT |
Fieldbus interface, type of connection |
2x socket |
Fieldbus interface, connection technology |
M12x1, D-coded in accordance with EN 61076-2-101 |
Fieldbus interface, number of pins/wires |
4 |
Fieldbus interface, electrical isolation |
Yes |
Fieldbus interface, transmission rate |
100 Mbit/s |
Internal cycle time |
1 ms per 1 byte of user data |
Maximum address volume for inputs |
64 Byte |
Maximum address volume for outputs |
64 Byte |
Power supply, function |
Electronics and load |
Power supply, type of connection |
Plug |
Power supply, connection technology |
M12x1, A-coded in accordance with EN 61076-2-101 |
Power supply, number of pins/wires |
5 |
Diagnosis |
Communication error
System diagnostics
Undervoltage |
Additional functions |
Conformance class C
Fast Start Up (FSU)
LLDP
MRP
PROFINET IRT
PROFIenergy
SNMP
Shared device
Web servers |
Configuration support |
GSDML file |
Product-specific LED display |
PS: operating voltage for electronics and load supply
X1: System status module I port 1
X2: System status module I port 2 |
Bus-specific LED display |
NF: Network error
TP1: network active, port 1
TP2: network active, port 2 |
Operating voltage range DC |
18 ... 30 V |
Nominal operating voltage DC |
24 V |
Intrinsic current consumption at operating voltage |
Typically 80 mA |
Max. power supply |
4 A |
Authorisation |
RCM Mark
c UL us - Listed (OL) |
KC mark |
KC-EMV |
CE mark (see declaration of conformity) |
to EU directive for EMC |
Corrosion resistance classification CRC |
2 - Moderate corrosion stress |
Storage temperature |
-20 ... 70 °C |
Protection class |
IP65
IP67 |
Note on degree of protection |
in assembled condition
Unused connections sealed |
Ambient temperature |
-5 ... 50 °C |
Material housing |
PA |
Materials note |
Contains PWIS substances
Conforms to RoHS |