Pressure by regulators to set up an electrical signal.
-
Precision Control
-
1.5% FS linearity, precision control is possible that pressure hysteresis 1.0% FS.
-
Excellent pressure characteristics
-
Output voltage variation for the primary pressure change is less than 0.5% FS.
-
Flow characteristic
-
As with the normal pressure reducing valve, ensuring a ready flow directly to the pneumatic equipment. In addition, reproducibility for intermittent load is less than 0.5% FS.
-
Free mounting orientation
-
There are no restrictions on mounting orientation. However, after installation is required zero and span adjustments.
-
Wide adjustment range
-
The span adjustment screw, RT · E/P-8-2 is 0.65 ~ 0.84MPa, RT · I/P-8-2 can change its point of each span in the range of 0.24 ~ 0.84MPa.
-
Compact
-
Compact main dimensions of 54 × 105. Takes up space.
RT · E/P-8-2 |
RT · I/P-8-2 |
RT · I/P-1-2 |
Fluid |
Compressed air cleaning |
Pressure range (MPa) |
0.02 to 0.82 |
0.02 to 0.1 |
Outlet pressure range of 1 (MPa) |
1.MAX,
Above the set pressure +0.035 |
0.7.MAX,
Above the set pressure +0.02 |
Input signal |
Control scheme |
Voltage 2-wire |
Current 2-wire |
Voltage (VDC) |
0-10 |
- |
Input Impedance (Ω) |
805 |
- |
Current (mADC) |
- |
4-20 |
Input Impedance (Ω) |
- |
260 |
180 |
Linearity (%. FS) |
1.5 |
Hysteresis (%. FS) |
1.0 |
Repeatability (%. FS) |
± 0.1 |
± 0.5 |
Step response (sec) |
1.0 |
0.2 |
Lower limit span adjustment (MPa) |
0.65 |
0.24 |
0.08 |
Sensitivity Relief (MPa) |
Below the set pressure + 0.001 |
Air consumption (Nl / min) |
Below 3.7 |
Below 4.8 |
Operating Temperature Range (℃) |
5-60 |
Port size (Rc) |
1 / 4 |
Pressure gauge port size (Rc) |
1 / 4 |
Bracket |
Standard equipment |
Weight (kg) |
0.94 |