AC Clamp Meters
|
Model
|
2608A
|
2805
|
2006
|
2007A
|
2031
|
Appearance
|
|
|
|
|
|
Display
|
Analogue
|
Analogue
|
Didital
|
Didital
|
Didital
|
Sample rate
|
-
|
-
|
2counts
/sec
|
Approx.2.5 counts/sec
|
2counts
/sec
|
Detection method
|
MEAN
|
MEAN
|
MEAN
|
MEAN
|
MEAN
|
Frequency responce
|
50/60Hz
|
50/60Hz
|
40Hz~1kHz
|
40~400Hz
|
40Hz~1kHz
|
Conducttor size(MAX.mm)
|
ø33mm
|
ø35mm
|
Ø19mm
|
ø33mm
|
Ø24mm
|
Model
|
2017
|
2027
|
2040
|
2002PA
|
2002R
|
Appearance
|
|
|
|
|
|
Display
|
Didital
|
Didital
|
Didital
|
Didital
|
Didital
|
Sample rate
|
Approx.2.5 counts/sec
|
Approx.2.5 counts/sec
|
3counts
/sec
|
Approx.2.5 counts/sec
|
Approx.2.5 counts/sec
|
Detection method
|
MEAN
|
MEAN
|
MEAN
|
MEAN
|
MEAN
|
Frequency responce
|
45Hz
|
40Hz~1kHz
|
40~400Hz
|
40Hz~1kHz
|
40Hz~1kHz
|
Conducttor size(MAX.mm)
|
ø33mm
|
ø33mm
|
ø33mm
|
Ø55mm
|
Ø55mm
|
|
AC/DC Clam Meters
|
MODEL
|
2010
|
2004
|
2033
|
2037
|
2046R
|
Appearance
|
|
|
|
|
|
Display
|
Digital
|
Digital
|
Digital
|
Digital
|
Digital
|
Sample rate
|
Approx. 3 counts/sec
|
Approx. 3 counts/sec
|
Approx. 2.5 counts/sec
|
Approx. 3 counts/sec
|
3counts/sec
|
Detection method
|
MEAN
|
MEAN
|
MEAN
|
RMS
|
RMS
|
Frequency response
|
DC, 40HZ~2kHz
|
DC, 40HZ~1kHz
|
DC, 20HZ~1kHz
|
DC, 10HZ~1kHz
|
DC,
40~400Hz
|
Conductor size (MAX.mm)
|
Ø7.5mm
|
Ø19mm
|
Ø24mm
|
Ø33mm
|
Ø33mm
|
MODEL
|
2055
|
2056R
|
2003A
|
2009A
|
2300R
|
Appearance
|
|
|
|
|
|
Display
|
Digital
|
Digital
|
Digital
|
Digital
|
Digital
|
Sample rate
|
3counts/sec
|
3counts/sec
|
Approx. 2.5 counts/sec
|
Approx. 3 counts/sec
|
Approx. 2 counts/sec
|
Detection method
|
MEAN
|
RMS
|
MEAN
|
RMS
|
RMS
|
Frequency response
|
DC,
40~400Hz
|
DC,
40~400Hz
|
DC, 40HZ~1kHz
|
DC, 30HZ~1kHz
|
50/60Hz
|
Conductor size (MAX.mm)
|
Ø40mm
|
Ø40mm
|
Ø55mm
|
Ø55mm
|
Ø10mm
|
|
Leakage Clamp Meters
|
MODEL
|
2431
|
2432
|
2433
|
2433R
|
2412
|
Appearance
|
|
|
|
|
|
Display
|
Digital
|
Digital
|
Digital
|
Digital
|
Digital
|
Sample rate
|
2counts/sec
|
Approx. 2.5 counts/sec
|
Approx. 2.5 counts/sec
|
Approx. 2.5 counts/sec
|
Approx. 3 counts/sec
|
Detection method
|
MEAN
|
MEAN
|
MEAN
|
RMS
|
MEAN
|
Frequency response
|
40~400Hz
|
20Hz~1kHz
|
20Hz~1kHz
|
20Hz~1kHz
|
40~400Hz
|
Conductor size (MAX.mm)
|
Ø24mm
|
Ø40mm
|
Ø40mm
|
Ø40mm
|
Ø40mm
|
MODEL
|
2434
|
2417
|
2413F
|
2413R
|
|
Appearance
|
|
|
|
|
Display
|
Digital
|
Digital
|
Digital
|
Digital
|
Sample rate
|
Approx. 2.5 counts/sec
|
Approx. 3 counts/sec
|
Approx. 3 counts/sec
|
Approx. 3 counts/sec
|
Detection method
|
MEAN
|
RMS
|
MEAN
|
RMS
|
Frequency response
|
40~400Hz
|
40HZ~1kHz
|
40HZ~1kHz
|
40HZ~1kHz
|
Conductor size (MAX.mm)
|
Ø28mm
|
Ø40mm
|
Ø68mm
|
Ø68mm
|
Kyoritsu Vietnam
GNN VIETNAM
Headquarter Office: 153 Nguyen Van Thu, Đakao Ward, Dist.1, HCMC.
Transaction Office: 33 Hoa Hong, Ward 2, Phu Nhuan District, HCMC.
Tel : (084.8) 3 517 4923 I Fax: (084.8) 3 517 4924
Email: contact@gnnvietnam.com